The NEW Differential Refractive Index Detector for HPLC, GPC/SEC
The new Refractive Index Detector RI 2012 series provides a consistent enhancement of the already successfully established Refractive Index Detector models RI 2000 and RI 2000-F. The Refractive Index Detector RI 2012 series offers users 3 times higher sensitivity, (compared to RI 2000) stability and reproducibility required for optimal refractive index detection in HPLC and GPC/SEC. The new Refractive Index Detector RI 2012 series provide autopurge and autozero capabilities, as well as RS-232 and USB communication to acquire data directly without using any external signal interface.
Note: For all International Orders, the buyer will be solely responsible for the customs clearance, duty, and taxes imposed on the package.
Refractive Index Detector RI 2012 detectors are available for:
- micro
- analytical
- semipreparative mode
RI 2012 M / micro |
RI 2012 A / analytical |
RI 2012 P/ semiprep |
Detection Method |
Deflection Deflection Deflection |
Refractive Index Range |
1.00 to 1.75 1.00 to 1.75 1.00 to 1.75 |
Flow Rate |
0,2 - 3,0 ml/min |
0,2 - 3,0 ml/min |
5,0 - 50 ml/min |
Flow Cell Volume |
4ul, 45 degree angle |
9ul, 45 degree angle |
13ul, 5 degree angle |
max. Flow Cell Pressure |
6 kg/cm2 6 kg/cm2 6 kg/cm2 |
Dead Volume |
Into cell 6ul |
Into cell 24ul |
Into cell 88 or 314ul |
Linearity Range |
0-500ul RIU |
0-1000 uRIU |
0-20000 uRIU |
Noise Level |
10 x 10-9 RIU |
5 x 10-9 RIU |
10 x 10-8 RIU |
Autozero Range |
Full Range |
Full Range |
Full Range |
Drift with 1ml H2O/min |
< 1 mV/hour |
< 1 mV/hour |
< 1 mV/hour |
Purge Valve |
yes |
yes |
Yes/No (depends on flow) |
Integrator Output |
+/- 1 Volt |
Recorder Output |
+/- 10 mV / 100 mV / 1Volt |
Recorder Offset |
0 mV/ 10 mV/ 100 mV |
Recorder Range |
8 steps (1:8) - (16:1) |
Marker |
Yes / No |
Digital Interface |
Control of: Purge, Autozero, Start, Stop, Heater, Data output rate, Polarity Current output of: Temperature optical bench, Optical balance, sum voltage, difference voltage, Alarm (Signal too high/low, A/D out of range, no temp. sensor) |
Digital Output |
TTL: Intensity Alarm |
Digital Input |
TTL: Purge, Autozero, Start/Marker |
Temperature Setting |
Ambient, 35 degree C to 55 degree C in 1 degree C steps, Thermal Fuse 70 degree C |
Time Constant |
RAW (0,0 sec), Fast (0,4 sec), Medium (0,8 sec), Slow (1,2 sec) |
Power Source |
AC 100-120/220-240V, 50/60 Hz, 50VA |
Dimensions in cm |
300mm x 440mm x 175mm (W x D x H) |
Weight |
9,6 kg |
Cat.-No.: |
Description |
RI 2012 A |
Differential Refractive Index Detector, Analytical |
RI 2012 M |
Differential Refractive Index Detector, Micro |
RI 2012 P |