Minisart SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17574 with a pore size of 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
Non-sterile Minisart SRP syringe filters are supplied in a pouch in one pack. This reduces waste and makes the handling easier whenever the application allows clarification under non-sterile conditions, like this is the case for the majority of sample preparation steps prior to HPLC or GC analysis. The low-binding PTFE membrane is the best option for leachable free filtration whenever highest chemical compatibility and pH values of 1 - 14 are needed. For hydrophilic solutions pre-rinsing with a solvent is necessary to make the hydrophobic membrane permeable for aqueous liquids. Due to the hydrophobic nature Minisart SRP can also be used for venting. The housing of the filter is made of PP (polypropylene) which is compatibility with harsh solvents, acids and bases.
- A pouch in one pack for less waste
- Minimum extractables or leachables
- Highest chemical compatibility
- Suitable as venting filter
Note: For all International Orders, the buyer will be solely responsible for the customs clearance, duty, and taxes imposed on the package.
Applications
- Analytical Sample Preparation
- Clarification
Specifications
- Connector Inlet: Female Luer Lock
- Connector Outlet: Male Spike
- Filter Diameter: ⌀ 15 mm
- Filtration Area: 1.7 cm²
- Housing Dimensions: 25 × 23 mm
- High Flow: No
- Filter Paper/Membrane Color: White (opaque)
- Flow Rate: 150 mL/min with methanol at 1 bar (14.5 psi) | 1600 mL/min with air at 0.1 bar (1.5 psi)
- Total Throughput: Up to 15 mL
- pH Range: 1.0 – 14.0
- Housing Material: Polypropylene (PP)
- Membrane Material: Polytetrafluorethylene (PTFE)
- Maximum Allowable Working Temperature: 121 °C (250 °F)
- Maximum Inlet Pressure: 4.5 bar (65 psi)
- Maximum Operating Pressure: 4.5 bar (65 psi)
- Operating Pressure: 4.5 bar (65 psi)
- Bubble Point: Min. value with ethanol 0.9 bar (13 psi)
- Burst Pressure: Min. value 7.0 bar (102 psi)
- Non-Fiber Releasing: This filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
- Pore Size: 0.45 µm
- Wettability: Hydrophilic
- Device Type: Syringe Filters
- Sample Type: Air/Gas, Solvents, Harsh liquids
- Sterilization Method: Ethylene Oxide, Autoclave
- Delivery Condition: Non-Sterile
- Sterilization Procedures: Ethylene oxide, Autoclave, 121°C, 30 min
- Hold-up Volume: 30 – 100 µL before bubble point